DATA LOGGER

DATA LOGGER WinC-I

Data Logger / Controller - WinC-I Specifications:

400MHz main CPU

64MB SDRAM Onboard

64MB ON-Board Flash Memory

One 100M Ethernet

3.5” 262K Colour LCD

8Ch 12Bit ADC,

4 Digital I/O with one pulse counter

3 Serial Ports – 1 RS232/RS485

One USB Host and One USB Slave

One SD Card Interface

WindowsCE.NET 5.0 OS

In-built RTC with battery on board

Upto 99 sensors can be connected over RS485 Bus

Extremely Low Power Consumption, hence, can be used in remote locations with Battery & Solar Power.

HEXATRIK Make Automatic Weather Station – WinC-I automatically collect the information from attached sensors, process the same and store them into its memory as per the pre-programmed interval (also as per IMD standard) or any other user-defined interval. WinC-I has an inbuilt QVGA Colour LCD display in the front panel. There are built-in high performance Microsoft Windows CE based computing program which calculates the weather parameters coming from sensors such as Temperature, Humidity, electro-mechanical wind sensors or Ultra-Sonic Wind sensors, Atmospheric Pressure etc.. Built-in digital channels - one RS-232/RS485 and three UART Channels, and one USB channel available to interface different types of sensors. GSM/GPRS or RF Modem interfaced to the data logger.

Product of:

HEXATRIK Electronics

MIG A 156, Dr A S Rao Nagar, ECIL Post, Hyderabad, AP 500 062, BHARATH (India). E-mail: info@hexatri.in. www.hexatrik.in
Ph: +914065 279032
Note: Specifications subject to change. Please confirm at the time of purchase. Above picture is indicative only. Model varies as per requirement.

Back to Top

DATA LOGGER (DL0812)

DL0812 is one of the HEXATRIK’s efficient Data Logger - automatically collects the information from attached sensors, process the same and store them into its memory as per the pre-programmed interval or any other user-defined interval. Data logger has a keypad option and 2 line backlit LCD display in the front panel.

There are built-in 12 high performance analog channels, 4 digital channels, one RS-232/RS485 Port in the form of standard DB9 connector, and one RS-485 channel available to interface different types of sensors. Data including the setup and program files shall be transferable from the system via RS232 port to PC Memory stick. DL0812 can also transmit data with the help of GSM/GPRS modems.

Data Logger Specifications:

ADC Resolution : 8Ch@12bit System

Clock : RTC/GSM

Operating Temperature range: 00C to +550C

Internal Memory : Up to 4MB

Battery Backup : External

Sample Intervals : 1Sec minimum

Visual display : 2 Line/16Ch LCD

Power consumption : Less than 150uA while idle, Less than 150mA while running with out sensors

Battery Charge controller : External

Sensor Interface: DL0812 compatible with all type of sensors like Air Temperature, Humidity, Wind Speed & Direction, Solar Radiation, Rain Gauge, Soil Temperature, Soil moisture, leaf wetness, Pressure etc. It can be configured to read from any type of Sensor with o/p of current, voltage, frequency, resistance, pulse, event etc.

Product of:

HEXATRIK Electronics

MIG A 156, Dr A S Rao Nagar, ECIL Post, Hyderabad, AP 500 062, BHARATH (India). E-mail: info@hexatri.in. www.hexatrik.in
Ph: +914065 279032
Note: Specifications subject to change. Please confirm at the time of purchase. Above picture is indicative only. Model varies as per requirement.

Back to Top

DATA LOGGER DL0312-RS485

HEXATRIK Make Data loggers DL0312-RS485 - automatically collects the information from attached sensors, process the same and stores them into its memory as per the pre-programmed interval or any other user-defined interval. Data logger has a keypad option and 2 line backlit LCD display in the front panel.

There are 3 built-in high performance analog channels in the form of standard Terminal block connector available to interface different types of sensors. Data including the setup and program files shall be transferable from the system via RS-485 channel IN and OUT

DL0312-RS485 Specifications:

ADC Resolution : 3Ch@12bit

System clock : RTC Operating

Temperature range : 00C to +550C

Internal Memory : Up to 4MB

Power Supply : External

Sample Intervals : 1Sec Minimum

Power consumption : Less than 150uA while Idle, < 150mA while running with-out sensors.

Sensor Interface: DL0312 compatible with all type of sensors like Air Temperature, Humidity, Wind Speed and direction, Solar Radiation, Rainfall, Soil Temperature, Soil moisture, leaf wetness etc. It can be configured to read from any type of sensors such as thermocouples or thermisters.

Product of:

HEXATRIK Electronics

MIG A 156, Dr A S Rao Nagar, ECIL Post, Hyderabad, AP 500 062, BHARATH (India). E-mail: info@hexatri.in. www.hexatrik.in
Ph: +914065 279032
Note: Specifications subject to change. Please confirm at the time of purchase. Above picture is indicative only. Model varies as per requirement.

Back to Top

WinC-II MaWeT

WinC-II MaWeT Specifications:

400MHz main CPU

64MB SDRAM Onboard

256MB ON-Board Flash Memory

One 100M Ethernet

7” 262K Colour LCD

3 Serial Ports – 1 RS232/RS485

One USB Slave

WindowsCE.NET 5.0 OS

This System AUTOMATIC MARINE WEATHER TERMINAL is designed by HEXATRIK keeping in view the basic requirements of the Meteorological Data required during the course of sailing for a ship. Being fully solid-state (no moving parts), the system provides reliable, accurate and virtually maintenance-free Meteorological Data. The system provides the following data via RS232 serial port:-

Relative Wind Speed and Relative Wind Direction

True Wind Speed and True Wind Direction

Temperature

Humidity

Atmospheric Pressure (QFE)

Atmospheric Pressure(QNH)

Latitude

Longitude

COG (Course on Ground)

SOG (Speed on Ground)

Product of:

HEXATRIK Electronics

MIG A 156, Dr A S Rao Nagar, ECIL Post, Hyderabad, AP 500 062, BHARATH (India). E-mail: info@hexatri.in. www.hexatrik.in
Ph: +914065 279032
Note: Specifications subject to change. Please confirm at the time of purchase. Above picture is indicative only. Model varies as per requirement.

Back to Top

Electrical Anemograph

Wind Computer with 32bit Microcontroller

2 Pen 100mm Strip chart recorder

Ultra Sonic Anemometer

Local Data repeater

Wind Speed Range: 0 – 200KM/Hr

Wind Direction Range: 0 – 360 degree

Operating Temperature: -20° to + 60°C

HEXATRIK Make Wind Computer – WinC-I configured as Electrical Anemograph automatically collect the information from attached sensors, process the same and store them into its memory as per the pre-programmed interval (IMD standard) or any other user-defined interval. WinC-I has a keypad option and 2 line backlit LCD display in the front panel. There are built-in high performance wind computing program which calculates True wind speed and True wind direction from apparent wind sensors such as electro-mechanical wind sensors or Ultra-Sonic Wind sensors. Built-in digital channels - one RS-232/RS485 port in the form of standard DB9 connector, and one RS-485 channel available to interface different types of sensors. Optional GSM/GPRS or RF Modem interfaced to the data logger.

Product of:

HEXATRIK Electronics

MIG A 156, Dr A S Rao Nagar, ECIL Post, Hyderabad, AP 500 062, BHARATH (India). E-mail: info@hexatri.in. www.hexatrik.in
Ph: +914065 279032
Note: Specifications subject to change. Please confirm at the time of purchase. Above picture is indicative only. Model varies as per requirement.

Back to Top